Building Management Systems (0-10v)

   Single Phase Motors (220/240v)

This range of motor speed controls has been developed to meet the growing demand for the control of fans and centrifugal pumps that form part of a Building Management System (BMS).  This units accept d.c voltage signals direct from sensors for proportional control or through D.D.C micro-processor systems, often providing alternative proportional integral (PI) control.

CJ
Control Features
Variable motor speed via external process control signal
Signal 0-10v d.c standard or 4-20mA/0-20v phase cut built to order
Printed circuit board or in enclosure to IP55
Adjustable minimum speed and maximum speeds
Hard Start
0-10 v dc signal fan controller for single phase motor

Model No. 3 6 8
Full Load Current (amps) 3.0 amps 6.0 amps 8.0 amps
Start Current (amps) 6.0 amps 12.0 amps 20.0 amps
Supply voltage* 220/240v, 50/60Hz
* We can design unit to suit other supply voltages and frequencies

   Three phase motors 380/415v please see Frequency Inverters

Sensors
The standard input is a 0-1-volt d.c signal.  Units to receive inputs such as 4-20mA or 0-20v phase cut can be made to order.


Cooling

General
A dedicated range of automatic fan speed controls utilising a thermistor mounted in a perforated plastic tube sensing air temperature.
A non standard unit is available for sensing two temperature zones and varying fan speed according to temperature differential.
This control type is used for destratification of air for heat economy in high buildings.

BJ
Control Features
Infinitely variable speed control
External set point temperature adjustment
Adjustable minimum speed setting
Dedicated temperature sensors
On/Off switch
Hard Start
Temperature sensed automatic fan speed control for heating or cooling applications
 
Model No. 2 8
Full Load Current (amps) 2.0 amps 8.0 amps
Start Current (amps) 4.0 amps 20.0 amps
Supply voltage* 220/240v, 50/60Hz
* We can design unit to suit other supply voltages and frequencies
 

Heating

General
Developed to control heat output from fan assisted convector heaters incorporating hot water coils or from small air handling units. The control output is automatically discontinued when sensed temperature necessary to run fan motor at minimum speed drifts 1ºC outside the control proportional band.

FJ
Control Features
Infinitely variable speed control
Adjustable maximum and minimum speeds
Switch selectable heating or cooling mode
Fixed proportional band
Cut off mode
Adjustable set point
Temperature sensed automatic motor speed control for heating or cooling applications
 
Model No. 2
Full Load Current (amps) 2.0 amps
Start Current (amps) 4.0 amps
Supply voltage* 220/240v, 50/60Hz

* We can design unit to suit other supply voltages and frequencies

Please contact SEL for more information on any products shown on this page.

Stock Electronics reserve the right to add features to their controls as the market palace demands. The features highlighted in this product sheet can form the basis of purpose made controls to meet the individual requirements of design engineers.

 

AUTOMATIC SPEED CONTROL FOR SINGLE PHASE FANS AND CENTRIFUGAL PUMPS
Using Dedicated Sensors or Process Control Signal Outputs